  • At a recent supplier day event, Hitran was recognized with a coveted Supplier Recognition Award by a very prestigious OEM. The award represented our customer's recognition of the complete team effort and manufacturing quality at Hitran. Our engineering, manufacturing and sales support allowed them to have a very successful market entry with a major new product in the alternative energy market.

 

 

 

General Purpose Transformer

 

 

Download PDF: click here
View as Webpage: click here

 

 

GPT SERIES DRY TYPE
  • SINGLE PHASE / THREE PHASE
    UL LISTED 3 - 500 KVA
  • Provides electrical isolation and voltage
    transformation.
  • Use for in-house applications: industrial,
    commercial or institutional
  • Safe, quiet and reliable
  • UL listed (through 500 KVA). All units designed
    and built in full compliance with NEMA and ANSI
    requirements
  • Sizes 3KVA through 1000 KVA
  • Designed, manufactured and serviced with over
    45 years experience in standard and specialty
    transformers

 

 

SINGLE PHASE · 60 HERTZ · 600 VOLT CLASS · 150° C RISE/220° C CLASS · NEMA 1 ENCLOSED
- - DIMENSIONS IN INCHES** APPROX. TYPE***
KVA CAT NO.* H W D WT. LBS. MOUNTING
3.0 G10003PSF6 14.25 8.38 9.88 60 Wall
5.0 G10005PSF6 15.38 8.38 9.88 90 Wall
7.5 G10007PSF6 16.75 8.38 9.88 110 Wall
10.0 G10010PSH6 23.63 19.5 18 140 Floor/Wall
15.0 G10015PSH6 29.5 20.75 18.75 155 Floor (W)
25.0 G10025PSH6 29.5 20.75 18.75 210 Floor (W)
37.5 G10037PSH6 29.5 20.75 18.75 270 Floor (W)
50.0 G10050PSH6 33.75 24 19.75 345 Floor (W)
75.0 G10075PSH6 41 30 25 410 Floor
100.0 G10110PSH6 41 30 25 530 Floor
167.0 G10116PSH6 41 30 25 725 Floor

Standard Primary and Secondary Voltages available. (Insert code number listed for the respective letter in catalog number.)

 

PS VOLTAGE CODE NO.

PRIMARY VOLTAGE

PRIMARY
TAPS1

SECONDARY VOLTAGE

3 - 15 KVA

11 240x480 None 120/240

21

208

(4)-2.5%

120/240

31

277

(4)-2.5%

120/240

41

480

(4)-2.5%

120/240

51

600

(4)-2.5%

120/240

25 - 167 KVA

61

240x480

(2)+(4)-2.5%

120/240

51

600

(4)-2.5%

120/240

1) Plus (+) & Minus (-) taps are FCAN and FCBN respectively (Full Capacity Above and Below Nominal).
2) Tap configuration shown is for 480V. Taps on the 240V winding are (1)+(2)-5%.

Lower Temperature Rise Option available at slight extra cost.
(Replace letter in next to last field of catalog number with code letter listed for desired temperature rise.)

 

Temp Rise / Insulation Class Code Letter
110°C rise / 220°C Class . . . . . . . . . . . . F (Standard Rise for 3-7.5KVA
85°C rise / 220°C Class. . . . . . . . . . . . . .B

 

**Dimensions listed are not to be used for construction purposes.
***3-7.5KVA units are designed for wall mounting. 10KVA units can be either floor or wall mounted. Standard units above 10 KVA are designed for floor mounting. Wall mounting brackets are available thru 50 KVA at slight extra cost.

 

THREE PHASE · 60 HERTZ · 600 VOLT CLASS · 150° C RISE/220° C CLASS · NEMA 1 ENCLOSED

DIMENSIONS IN INCHES**

APPROX.

TYPE***

KVA

CAT NO.*

H

W

D

WT. LBS.

MOUNTING

3.0

G30003PSF6

16

15

14

100

Floor/Wall

6.0

G30006PSF6

16

15

14

125

Floor/Wall

9.0

G30009PSF6

23.63

19.5

18

145

Floor/Wall

15.0

G30015PSH6

23.63

19.5

18

170

Floor/Wall

25.0

G30025PSH6

29.5

20.75

18.75

230

Floor (W)

30.0

G30030PSH6

29.5

20.75

18.75

265

Floor (W)

37.5

G30037PSH6

29.5

20.75

18.75

310

Floor (W)

45.0

G30045PSH6

29.5

20.75

18.75

340

Floor (W)

50.0

G30050PSH6

29.5

20.75

18.75

380

Floor (W)

75.0

G30075PSH6

33.75

24

19.75

460

Floor (W)

112.5

G30111PSH6

41

30

25

750

Floor

150.0

G30115PSH6

41

30

25

1000

Floor

225.0

G30122PSH6

48

48

32

1225

Floor

300.0

G30130PSH6

48

48

32

1750

Floor

400.0

G30140PSH6

60

54

40

2200

Floor

500.0

G30150PSH6

60

54

40

2600

Floor

750.0

G30175PSH6

72

60

48

3800

Floor

1000.0

G30210PSH6

90

72

60

5200

Floor

Standard Primary and Secondary Voltages available. (Insert code number listed for the respective letter in catalog number.)

 

PS VOLTAGE CODE NO.

PRIMARY VOLTAGE

PRIMARY
TAPS1

SECONDARY VOLTAGE

3 - 15 KVA

11

240 DELTA

(2) - 5%

208Y/120

21

480 DELTA

(2) - 5%

2008Y/120

22

480 DELTA

(2) - 5%

240Δ4

31

600 DELTA

(2) - 5%

208Y/120

25 - 1000 KVA

41

240 DELTA

(4) - 2.5%3

208Y/120

51

480 DELTA

(2) + (4) - 2.5%

208Y/120

52

480 DELTA

(2) + (4) - 2.5%

240 DELTA 4

53

480 DELTA

(2) + (4) - 2.5%

480Y/277

61

600 DELTA

(2) + (4) - 2.5%

208Y/120

 

Note: 25, 37.5 and 50 KVA units are availalbe with Voltage Code 51 and 53 only 1) Plus (+) & Minus (-) taps are FCAN and FCBN respectively (Full Capacity Above and Below Nominal). 3) Tap configuration shown is for 480V. Taps on the 240V winding are (1)+(2)-5%. 4) Center tapped 120 V secondary available at slight additional cost. The tap is on one phase with a 5% maximum capacity rating.

Lower Temperature Rise Option available at slight extra cost.

(Replace letter in next to last field of catalog number with code letter listed for desired temperature rise.)

Temp Rise / Insulation Class Code Letter
110°C rise / 220°C Class . . . . . . . . . . . . F (Standard Rise for 3, 6 & 9KVA)
85°C rise / 220°C Class. . . . . . . . . . . . . .B

 

**Dimensions listed are not to be used for construction purposes.

***3-15KVA units can be either wall or floor mounted.

Standard units above 15 KVA are designed for floor mounting. Wall mounting brackets are available thru 75 KVA at slight extra cost.

CONNECTION DIAGRAMS

 

- PS
CODE
PRIMARY
VOLTAGE & TAPS1
CONN.
TABLE
SECONDARY
VOLTAGE
SCHEMATIC
1PH 11 240 x 480V A 120/240V
LOAD CONNECT VOLTAGE
X1-X4 X2-X3 240
X1-X3 &
X2-X4
120

21
31
41
51
208V (4) - 2.5%
277V (4) - 2.5%
480V (4) - 2.5%
600V (4) - 2.5%
B
B
B
B
61 240 x 480V
(2( + (4) - 2.5%
C
3PH 11
21
31
240V (2) - 5%
480V (2) - 5%
600V (2) - 5%
D
D
D
208Y/120
41 240V (4) - 2.5% B
51
61
480V (4) - 2.5%
600V (4) - 2.5%

E
E

53 240V (4) - 2.5% E 480Y/277
22


52
480V (2) - 5%


480V (4) - 2.5%
D


E
240
DELTA

PRIMARY CONNECTION TABLES

 

A
CONNECT VOLTAGE
1-2 480
1-H2 &
2-H1
240
C
CONNECT VOLTAGE
1-2 105% 480V
1-4 102.5%
3-4 100%
3-6 97.5%
5-6 95%
5-8 92.5%
7-8 90% 240V
1-H2 &
2-H1
105%
3-H2 &
4-H1
100%
5-H2 &
6-H1
95%
7-H2 &
8-H1
90%
D
CONNECT VOLTAGE
1-2 100%
2-3 95%
3-4 90%
B
CONNECT VOLTAGE
2-1 100%
2-3 97.5%
4-1 95%
4-3 92.5%
4-5 90%
E
CONNECT VOLTAGE
1-2 105%
1-4 102.5%
3-2 100%
3-4 97.5%
3-6 95%
5-4 92.5%
5-6 90%

ENCLOSURE DATA

 

 

ISOLATION KVA RANGE vs. TEMPERATURE RISE (°C) ENCL.
STYLE
DIMENSIONS
1Ø KVA
150° RISE
1 Ø KVA
110° RISE
3Ø KVA
85° RISE
3Ø KVA
150° RISE
3Ø KVA
110° RISE
3Ø KVA
85° RISE
H W D D' A B A' B' C
- 3 - - - - 1 - - - - 12.5 - - - 10.5
- 5 3 - - - 1 - - - - 13.6 - - - 11.63
- 7.5 5 - - - 1 - - - - 15 - - - 13
- - - - 3.6 3 2 16 15 14 - 11 8 13.5 7.5 3.5
10 - 7.5 15 9 6-9 2 23.63 19.5 18 - 15.5 9 18.5 - -
15-37.5 10-25 10-25 25-50 15-37.5 37.5-50 3 29.5 20.75 18.75 - 19 11.5 - - -
50 37.5 - 75 45-50 37.5-50 3 33.75 24 19.75 - 22.25 12.5 - - -
75-167 50-100 37.5-100 112-150 75-112 75 3 41 30 25 - 27 18 - - -
- - - 225-300 150-225 112-150 3 48 48 - 32 - 29.5 46 - -
- - - 400-500 300-400 225-300 3 60 54 - 40 - 37.5 52 - -
- - - 750 500 400-500 4 72 60 48 - 28 43 - - -
- - - 1000 750 - 4 90 72 60 - 34 55 - - -