Hitran named supplier of the year for 2010

  • At a recent supplier day event, Hitran was recognized with a coveted Supplier Recognition Award by a very prestigious OEM. The award represented our customer's recognition of the complete team effort and manufacturing quality at Hitran. Our engineering, manufacturing and sales support allowed them to have a very successful market entry with a major new product in the alternative energy market.

 

 

 

Line Reactors

 

 

Download PDF: click here
View as Webpage: click here

 

 

 

 

 

 

 

HITRAN's standard line reactors are designed to minimize the problems associated with waveform distortion that occurs with equipment utilizing solid state switching devices.

 

Line Reactors are often used to · Reduce harmonics · Extend solid state switching device life · Reduce motor noise and temperature · Improve power factor · Filter power line irregularities · Reduce surge currents

Reactors are available in either 3% or 5% ratings. Typically a 3% reactor will be sufficient to handle most solid state switching applications and will filter normal line spikes and surges. Nuisance circuit breaker tripping can usually be avoided. A 5% reactor should be used where considerably higher line disturbances exist and compliance with IEEE 519 is desired. The 5% reactor is also the most effective at improving motor life by reducing the effects of harmonic currents.

 

Line Reactors
  • Dry Type
  • 3 Phase
  • 50/60hz
  • 600 Volt Class
  • Three Coil, Open Frame Construction

HITRAN's standard line reactors are designed to minimize the problems associated with waveform distortion that occurs with equipment utilizing solid state switching devices.

 

Line Reactors are often used to • Reduce harmonics • Extend solid state switching device life • Reduce motor noise and temperature • Improve power factor • Filter power line irregularities • Reduce surge currents

 

Reactors are available in either 3% or 5% ratings. Typically a 3% reactor will be sufficient to handle most solid state switching applications and will filter normal line spikes and surges. Nuisance circuit breaker tripping can usually be avoided. A 5% reactor should be used where considerably higher line disturbances exist and compliance with IEEE 519 is desired. The 5% reactor is also the most effective at improving motor life by reducing the effects of harmonic currents.

 

All Hitran line reactors can be used as either input or output reactors.

INPUT SIDE OF DRIVE OUTPUT SIDE OF DRIVE
When reactors are installed on the input side of drives, they reduce harmonic distortion from the drive onto the line. This installation setup will also limit voltage and current spikes and surges from the incoming line and reduces line notching.
By installing the reactor on the output side of the drive, the motor performance improves. This setup will improve the current and voltage waveforms from the supply, hence the noise emissions and motor overheating will be reduced. This installation will also protect the drive from short circuits at the load
MULTIPLE DRIVES MULTIPLE MOTORS
When multiple drives are installed on the power line, individual line reactors are recommended. Individual reactors provide isolated protection for each drive's own specific load and eliminates cross talk between multiple drives.
When there is a need for multiple motors on the same drive, a single reactor can be used. This application is for simultaneous operating motors only. The size of the reactor is based on the sum of horsepower of all motors

Hitran
Part #

iAMPS

LMH

VOLTAGE

208

240

380

415

480

600

AP2111

2

12.0

-

-

4% - 1HP

-

3% - 1-1HP

-

AP2112

2

20.1

-

-

-

4% - 1HP

5% - 1-1HP

3% - 1 - 1HP

AP2113

2

32.1

-

-

-

-

-

5% - 1 - 1HP

AP2114

4

3.1

3% - 1HP

3% - 1HP

-

-

-

-

AP2115

4

6.5

5% - 1HP

5% - 1HP

-

-

3% - 2-3HP

-

AP2116

4

9.1

-

-

4% - 1-2HP

4% - 2HP

5% - 2-3HP

3% - 3 - 5HP

AP2117

4

12.0

-

-

-

4% -1HP

-

5% - 2 - 3HP

AP2118

8

1.5

3% - 1-2HP

3% - 1-2HP

-

-

-

-

AP2119

8

3.1

5% - 1-2HP

5% - 1-2HP

-

-

3% - 5HP

3% - 7HP

AP2120

8

5.1

-

-

4% - 3HP

-

5% - 5HP

3% - 5HP / 5% - 7HP

AP2121

8

7.5

-

-

-

4% - 3HP

-

5% - 5HP

AP2122

12

1.25

3% - 3HP

3% - 3HP

-

-

-

-

AP2123

12

2.6

5% - 3HP

5% - 3HP

4% -7HP

3% - 7HP

3% - 10HP

AP2124

12

4.25

-

-

4% - 5HP

-

5% - 7HP

5% - 10HP

AP2125

18

0.81

3% - 5HP

3% - 5HP

-

-

-

-

AP2126

18

1.6

5% - 5HP

5% - 5HP

4% - 10HP

3% - 10HP

3% - 15HP

AP2127

18

2.5

-

-

-

4% - 10HP

5% - 10HP

5% - 15HP

AP2128

25

0.5

3% - 7HP

3% - 7HP

-

-

-

-

AP2129

25

1.2

5% - 7HP

5% - 7HP

4% - 15HP

4% - 15HP

3% - 15HP

3% - 20 - 25HP

AP2130

25

2.0

-

-

-

-

5% - 15HP

5% - 20 - 25HP

AP2131

35

0.40

3% - 10HP

3% - 10HP

-

-

-

-

AP2132

35

0.81

5% - 10HP

5% - 10HP

-

4% - 25HP

3% - 20 - 25HP

3% - 30HP

AP2133

35

1.2

-

-

4% - 20HP

4% - 20HP

5% - 20 - 25HP

5% - 30HP

AP2134

45

0.30

3% - 15HP

3% - 15HP

-

-

-

-

AP2135

45

0.71

5% - 15HP

5% - 15HP

4% - 25 - 30HP

4% - 30HP

3% - 30HP

3% - 40HP

AP2136

45

1.2

-

-

-

-

5% - 30HP

5% - 40HP

AP2137

55

0.25

3% - 20HP

3% - 20HP

-

-

-

-

AP2138

55

0.51

5% - 20HP

5% - 20HP

-

4% - 40HP

3% - 40HP

3% - 50HP

AP2139

55

0.85

-

-

-

-

5% - 40HP

5% - 50HP

AP2140

80

0.20

3% - 25HP

3% - 25 - 30HP

-

-

-

-

AP2141

80

0.41

5% - 25HP

5% - 25 - 30HP

4% - 40 - 50HP

4% - 50 - 60HP

3% - 50 - 60HP

3% - 60 - 75HP

AP2142

80

0.7

-

-

-

-

5% - 50 - 60HP

5% - 60 - 75HP

AP2143

100

0.15

3% - 30HP

3% - 40HP

-

-

-

-

AP2144

100

0.31

5% - 30HP

5% - 40HP

4% - 60HP

4% - 75HP

3% - 75HP

3% - 100HP

AP2145

100

0.45

-

-

-

-

5% - 75HP

5% - 100HP

AP2146

130

0.10

3% - 40HP

3% - 50HP

-

-

-

-

AP2147

130

0.21

5% - 40HP

5% - 50HP

-

4% - 100HP

3% - 100HP

3% - 125HP

AP2148

130

0.30

-

-

4% - 75HP

5% - 100HP

5% - 125HP

AP2149

160

0.75

3% - 50HP

3% - 60HP

-

-

-

-

AP2150

160

0.16

5% - 50HP

5% - 60HP

-

-

3% - 125HP

3% - 150HP

AP2151

160

0.23

-

-

4% - 100HP

-

5% - 125HP

5% - 150HP

AP2152

200

0.055

3% - 60HP

3% - 75HP

-

4% - 125HP

-

-

AP2153

200

0.12

5% - 60HP

5% - 75HP

-

-

3% - 150HP

3% - 200HP

AP2154

200

0.185

-

-

4% - 125HP

4% - 150HP

5% - 150HP

5% - 200HP

AP2155

250

0.045

3% - 75HP

3% - 100HP

-

-

-

-

AP2156

250

0.095

5% - 75HP

5% - 100HP

-

4% - 200HP

3% - 200HP

3% - 250HP

AP2157

250

0.150

-

-

4% - 150HP

-

5% - 200HP

5% - 250HP

AP2158

320

0.040

3% - 100HP

3% - 125HP

-

-

-

-

AP2159

320

0.080

5% - 100HP

5% - 125HP

-

-

3% - 250HP

3% - 300HP

AP2160

320

0.125

-

-

4% - 200HP

-

5% - 250HP

5% - 300HP

AP2161

400

0.030

3% - 125HP

3% - 150HP

-

-

-

-

AP2162

400

0.060

5% - 125HP

5% - 150HP

-

4% - 300HP

3% - 300HP

3% - 350 - 400HP

AP2163

400

0.105

-

-

4% - 250HP

4% - 250HP

5% - 300HP

5% - 350 - 400HP

AP2164

500

0.025

3% - 150HP

3% - 200HP

-

-

-

-

AP2165

500

0.050

5% - 150HP

5% - 200HP

4% - 350HP

4% - 350HP

3% - 350 - 400HP

3% - 500HP

AP2166

500

0.085

-

-

4% - 300HP

-

5% - 350 - 400HP

5% - 500HP

AP2167

600

0.020

3% - 2005HP

3% - 250HP

-

-

-

-

AP2168

600

0.040

5% - 200HP

5% - 250HP

-

-

3% - 500HP

3% - 600HP

AP2169

600

0.065

-

-

4% - 400HP

4% - 400HP

5% - 500HP

5% - 600HP

AP2170

750

0.015

3% - 250HP

3% - 300HP

-

-

3% - 600HP

-

AP2171

750

0.029

5% - 750HP

5% - 300HP

-

-

-

3% - 750HP

AP2172

750

0.048

-

-

4% - 500HP

4% - 500HP

5% - 600HP

5% - 750HP

Standard 3 Phase Line Reactor Specifications:

 

Voltage -
    600 Volts Maximum

                
Temperature rise  -
   130° Celsius

                
Cooling method  -
    Natural convection

                
Overload -
    150% rated 60 Hz current overload continuous

                
Enclosure - (optional)
    NEMA 1

                
Approvals -
    cUL approved
Ratings -
   Nominal Inductance ± 10% @ rated
          current,
   95% of nominal inductance @ 150%
          rated current,
   50% of nominal inductance @ 350% of
          rated current
Sound level -
    2 to 18 amps: 58 dBA, 30 to 320 amps: 70 dBA,
    25 to 100 amps: 64 dBA, 400 to 750 amps: 75 dBA